• Manlid Inside diameter: 465 mm
• Closures: 20 bolts
• Safety: relief valve 2 ‘’1/2 set at 7,30 bar, rupture disc at 8,07 bar, manometer 0/10 bar
• Liquid line: ball valve 1’’1/2 on dip tube
• Gas line: ball valve ¾’’
• Spare ports: 2 x double fittings 1’’1/2 & 2’’ with blind flanges
• Connections: PN16 flanges
Working Conditions
• Material: stainless steel 316 Ti / 1.4571
• Working pressure: + 6,66 / - 0,4 bar
• Test pressure: 10 bar
• Design Pressure RID: 21 bar
• IMDG equivalent thickness: 10 mm
• Code and Temperature design: ASME VIII-I / 93°C
Approvals
• RID / ADR Tank Code L21DH
• U.N. Tank transport instructions T 22
Options
*Other capacities: 1100 L
• Insulation
• Electrical or steam heating system
• Inside lining
• Pressure, temperature or level gauge